SB7257
Flow meter with integrated backflow prevention and
display
SBG32KM0FRKG
ifm electronic gmbh • Friedrichstraße 1 • 45128 Essen — We reserve the right to make technical alterations without prior notice. — EN-GB — SB7257-00 — 12.04.2021 —
Electrical data
Operating voltage [V]
18...30 DC; (to SELV/PELV; "supply class 2" to cULus)
Current consumption [mA]
< 50
Protection class
III
Reverse polarity protection
yes
Power-on delay time [s]
< 3
Outputs
Total number of outputs
2
Output signal
switching signal; analogue signal; frequency signal; IO-Link
Output function
normally open / normally closed; (parameterisable)
Max. voltage drop switching
output DC
[V]
2
Max. current load per output [mA]
150; (200: ...60 °C; Ambient temperature; 250: ...40 °C; Ambient temperature)
Analogue current output [mA]
4...20
Max. load [Ω]
500
Short-circuit protection
yes
Overload protection
yes
Frequency of the output [Hz]
0...10000
Measuring/setting range
Measuring range 8...200 l/min 0.48...12 m³/h 130...3170 gph 2.1...52.8 gpm
Display range 0...240 l/min 0...14.4 m³/h 0...3805 gph 0...63.4 gpm
Resolution 0.1 l/min 0.01 m³/h 1 gph 0.1 gpm
Set point SP 1.4...200 l/min 0.08...12 m³/h 20...3170 gph 0.3...52.8 gpm
Reset point rP 0...198.6 l/min 0...11.92 m³/h 0...3150 gph 0...52.5 gpm
Frequency end point, FEP 13.4...200 l/min 0.8...12 m³/h 210...3170 gph 3.5...52.8 gpm
In steps of 0.02 l/min 0.02 m³/h 5 gph 0.1 gpm
Frequency at the end point
FRP
[Hz]
10...10000
In steps of [Hz]
10
Measuring dynamics
1:50
In steps of
10 Hz
Temperature monitoring
Measuring range -10...100 °C 14...212 °F
Display range -32...122 °C -25.6...251.6 °F
Resolution 0.1 °C 0.1 °F
Set point SP -9.3...100 °C 15.2...212 °F
Reset point rP -10...99.3 °C 14...210.8 °F
In steps of 0.1 °C 0.2 °F
Frequency start point, FSP -10...78 °C 14...172.4 °F
Frequency end point, FEP 12...100 °C 53.6...212 °F
Frequency at the end point
FRP
[Hz]
10...10000
Accuracy / deviations
Flow monitoring
Accuracy (in the measuring
range)
± 5 % MEW; (Q > 1 l/min; 20...70 °C Medium temperature)